Installation Instructions for the ACS Electric Wiper
Retrofit
-
Completely remove the air wiper system,
including the controls.
-
Block the existing air supply.
-
Mount
the ACS unit to the existing mounting point.
-
Install
the electric controls in place of the air controls.
-
After
all parts are mounted, obtain power from a relay or circuit breaker
no greater than 10 Amps. Make the connection
to the RED wire from
the harness with a16 gauge wire. Black
wire to body ground. All other connections are preset on the wire
harness.
-
Test your Wipers.
ACS Wiper System - Driver
Controls
0 - Park Position - returns
wipers to starting point.
1 - Variable intermittent
operation
2 - Low Speed - operates at 33 cycles per minute.
3 - High Speed - operates at 51 cycles per minute.
WARNING: NEVER REACH INTO THE AREA OF ROD LINKAGE
WHEN THE SYSTEM IS RUNNING!